High Quality Energy Meter, Power Meter, Electronic Meter Suppliers in China

Home > Products > Energy Meter > Smart Multi-Function Energy Mete > Smart Multifunction Electric Energy Meter for Power Substation

Smart Multifunction Electric Energy Meter for Power Substation

Basic Info

Model No.:  DTSD1150

Product Description

Model NO.: DTSD1150 Installation: Direct Connected Electric Equipment: Three-phase Four-wire Power Meter Connection: Terminal Type: Energy Meter Customized: Customized Accuracy Class: 1.0 or 2.0 Current: 5(20)a, 10(40)a, 15(60)a, 10(60)a Pulse Constant(Imp/Kwh): 6400, 3200, 2400, 1600, 1200, 800, 400, 200 Display Type: LCD/LED Multi Tariff: Single Tariff or Multi Tariff Specification: CCC, CE, ISO9001, 14001, HS Code: 9028301400 Display: Indicator Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter Theory: Electronic Meter Measured Signal: Continuous Wave Certification: RoHS, ISO, CE Applicable Standard: IEC62053-21; IEC62052-11 Output Voltage: 3X220/380V Operating Temperature: -25~+60 Measuring Energy Range: Active or Reactive Communication: RS485 and Infrared Trademark: RADARKING Origin: Wuhan, China The meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-21 and class 2 three phase reactive energy meter in international standard IEC 62053-23.

It can accurately and directly measure 50 Hz or 60 Hz active energy consumption from three-phase four-wire AC electricity net. This meter has LCD monitors which shows the active energy power consumption, and there are far infrared and RS485 communication module in it ,with features of good reliability,, specious appearance etc and its feature of multi-functional make it convenient to contact with all kinds of AMR system.

Features:

1. Products Type-Three Phase Three Wires, Three Phase Four Wires.

2. Electric Power Measurement-Positive/ reverse active power, positive/reverse apparent power>, reactive power in 1,2,3,4 phase and active/reactive power in A, B, C phase which can be measured.  It can set tagged words of active and reactive group to restructure the positive/reverse active power and reactive power in 4 phases, and then for active group, reactive group1 and reactive group 2. It can storage power data for 12 settlement period.

3. Multi Tariff-It can set for 2 time zones, 2 programs of daily time and switching time (yy/mm/dd/hh/mm) of these two. Set for public holidays, date of each and meter number of daily time; Set for weekly holiday which controlled by its tagged words, and also set for meter number of daily time for each weekly holiday.

4. Demand Measuring-It can measure max demand and the time when it occurred for positive/ reverse active power, positive/reverse apparent power, reactive power in 1,2,3,4 phase, reactive group 1 and 2.

5. Event Log-With function for logging events such as no voltage, under voltage, over voltage, loss of phase, full loss of pressure, no current, over current and etc.

6. Electricity Freezing-With multi freezing ways of instantaneous freezing, timing freezing, day freezing, appoint freezing, on hour freezing and etc.

7. Load Profile-Support for 6 load data, and the time interval can be set for any time which from 1 to 60 mins. The time interval for each load can be the same or not.

8. Measure Function-It can measure voltage, current, phase angle, apparent power, active power, reactive power, power factor and grid frequency of total and each A, B, C phase, also it can show the direction of power. 

9. Communication Mode-Infrared+RS485 interface or double RS485 interface.

Rated current(A) 3×1.5(6), 3×5(20), 3×10(40), 3×15(60), 3×20(80), 3×80(100)
Rated voltage(V) Three-phase three-wire: 3×100V or 3×380V
Three-phase four-wire: 3×220/380V or 3×57.7/100V
Rated frequency(Hz) 50 or 60
Accuracy class Active:0.5, reactive:1.0 or active:1.0, reactive:2.0
Clock error ≤0.5sec/per day (reference temperature)
≤1.0sec/per day (backup battery)
Battery Global famous branded lithium battery; voltage: 3.0 or 3.6V;
capacity≥1000mAh; 1200bps-19200bps(programmable); update the data per 0.01 degree.
Double batteries to keep clock and related data; programmable alarming value ; Minimum 1 minute's interval for switching over undervoltage timing ,cut-out timing or energy tariff

*Please advise us if you need any different specifications,we can make according to your special requirement.

Transportaion & Storage Condition

The meters should be free from violent collision when being delivered or sealed off, and the buyer should in accord with the rules of ZBW003-82/84 for General Technical Conditions Of Instrument And Apparatus Packaging to transport and store them.

The meter should be stored in its original pack and the ambient temperature to keep them should be within -25ºC and 70ºC, there are no corrosive gas in the air.

The meter should be placed on the shelves in the warehouse and the stack height should be less than 5 cartons.

There shall be no harmful substance causing the corrosion in the air.

Contact us if you need more details on Energy Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Electronic Meter、Electricity Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Energy Meter > Smart Multi-Function Energy Mete