High Quality Energy Meter, Power Meter, Electronic Meter Suppliers in China

Home > Products > Energy Meter > Smart Multi-Function Energy Mete > AMR Smart Credit Charged Electronic Energy Power Meter

AMR Smart Credit Charged Electronic Energy Power Meter

Basic Info

Model No.:  DTZY150C

Product Description



Model NO.: DTZY150C


Installation: Direct Connected


Electric Equipment: Three-phase Four-wire


Power Meter Connection: Terminal


Type: Energy Meter


Customized: Customized


Voltage: 3X220/380V


Current: 5(40)a/5(60)a/10(60)a


Capacity of Lithium Battery: More Than 1.2ah


Communication Rate for Infrared: 1200BPS


Dimension: 112*160*58 Mm


Specification: CE, CCC, ISO9001, ISO14001


HS Code: 9028301100




Display: Digital


Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter


Theory: Electronic Meter


Measured Signal: Pulse Peak


Certification: RoHS, ISO, CE


Standards: IEC62053-21: 2003, Dl/T645-2007, GB/T17215.321,


Frequency: Class 2.0,1.0


Impulse Constant (Imp/Kwh): 6400, 3200, 2400, 1600, 1200, 800, 400, 200


Data Storage Period: More Than10 Years


Communication Rate for RS485: 2400BPS (Typical Value)


Trademark: RADARKING


Origin: Wuhan, China


Three phase four wire active energy meter is a induction meters which is applicable to measure 50 Hz or 60 Hz active energy consumption from three phase AC electricity net. All technical targets are completely conformed to National Standard GB/T15283-2008 and International Standard IEC62053-11. It has the features of tight structure design, high overload, low power loss, long service life, specious appearance, etc.



Functions



1. Energy Measurement:



Forward, Reversed and the sharp, peak, shoulder and off-peak combination active and reactive energy, Four-quadrant.



2. Frozen Function:



Timing frozen, Instantaneous frozen, Appointed frozen, Daily frozen, Measurement, Period frozen Energy.



3. Demand Record:



MD and time of the total, Sharp, Peak, shoulder, and off-peak of forward and reversed active.

MD and time of the total, Sharp, Peak, shoulder, and off-peak of combination reactive.

MD and time of the total, Sharp, Peak, shoulder, and off-peak of four-quadrant reactive.

Forward and reversed MD and time of the total Phase A, B, C.

Real-time Measurement: Measurement of Voltage, Current, Power, PF and Phase-angle.

Time Interval and Tariff: Four-kind of Tariff supported and two-set period.



4. Event Record:

missing voltage, under-voltage, over voltage, missing phase, completely missing voltage, current/voltage phase sequence reversed, current/voltage imbalance, missing current, cover opened, terminal opened, programming, MD cleared, energy cleared, clock calibration, etc.



5. Reading:

Manually reading: reading the data when press the up-button and down-button.

Reading by HHU(Hand Held Unit): reading the data through Infrared by HHU.

PC reading: reading the data by PC with RS485 communication port.

Reading when power off: when the power off, the meter can be woke up by the button, and then the data can be read from LCD display or by HHU automatically.



6. Display:

LCD display with backlight. The data can be display by pressing button or recycle display automatically.

Remote communication:

Data reading

Data saving

Clock calibration

Data accounting

Events record and reporting

Abnormal Alarm

Software update by remote or local communication

TCP, UDP, SMS message supported.

On-line supported

Routine data reported automatically can be set.

Important events reported automatically

Data flow can be accounted and limited



7. Communication:

RS485, Infrared, PLC, Wireless, GPRS/CDMA optional.. Prepayment with CPU Card, as well as remote prepayment with PLC, wireless, GPRS and others.




Technical standards
IEC 62052-11:2003 IEC62053-21:2003
GB/T 17215.211-2006,GB/T 17215.321-2008,
GB/T 17215.323-2008,GB/T 17215.301-2007,
DL/T 614-2007,DL/T645-2007,Q/GDW376.1-2009
Communication code PLC, Local RS485, Infrared


Spec.

Voltage

3x220/380V


Current

1.5(6)A/5(20)A/5(60)A/10(100)A
Voltage measurement
range
0.7Un---1.2Un
Accuracy class Active 1.0 class Reactive 2 class
Operating temperature
-25°C-- +55°C
Relative humidity ≤75%
Starting current Transformer connection type: 0.002ln (class1)
Overall power
consumption
1.5W,6A
Clock error ≤0.5s/d (23°C)
Battery life 10 years
The output pulse width (80±20) ms (DC)
Dimension 290mm X 170mm X 85mm (L x W x H)
Weight About 2.3Kg






Transportation & Storage

The goods should be free from violent collision when delivery and being sealed off, and as per the rules of GB/T13384-2008 General Technical Conditions Of Mechanical and Electronic Products Packaging to transport and store them.

Stack the inventory and storage on the shelves under the condition of original package and its height should be no more than 8 levels.

The place to store the goods should be clean and the temperature should be in the range of 0 and 40ºC as well as less than 85% of relative humidity; And the hazardous substance that would lead to the corrosion is not allowed to exist in the air .

Contact us if you need more details on Energy Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Multi-Tariff Meter、Electric Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Energy Meter > Smart Multi-Function Energy Mete