High Quality Water Meter, Flow Meter, Electronic Water Meter Suppliers in China

Home > Products > Water Meter > Remote Reading Water Meter > Intelligent Remote Radio Water Meter with Handheld Device

Intelligent Remote Radio Water Meter with Handheld Device

Basic Info

Model No.:  LXSG-25/FXD

Product Description



Model NO.: LXSG-25/FXD


Medium Temperature: Cold Water


Counter Instructions: Digital


Application: Civil


Medium Pressure: General Water Meter


Stucture: Wireless Communicating


Water Temperature: 0.1 ~ 30 Centigrades


Pressure Loss: Less Than 0.063MPa


Communication Interface: M-Bus


Installation: Horizontal


Packaging Detail: Carton Box Package


Specification: CE, CCC, ISO9001, ISO4064


HS Code: 9028201000




Install: Horizontal


Level Measurement: B


Nominal Diameter: 15-50mm


Principle: Speed of Water Meter


Work Environment: Dry Water Meter


Accuracy Grade: Class B


Water Pressure: Less Than 1MPa


Readings: 0.0001 -- 9999


Material: Brass/Cast Iron


Type: Pulse Output


Trademark: RADARKING


Origin: Wuhan, China




1. Features:



--Magnetic drive, protected against external magnetic tampering;



--Vacuum sealed register, frost resistant, keeps clear reading for long time;



-Brass body;



--Brass body can be painted



--External adjusting device,;



--For cold water;



--Remote transmission device can be added upon request



--Many kinds of sensors, such as Reed Switch, Hall and Weagand can be supplied upon request Pulse output may be 1l/pulse ,10l/pulse ;



--The meters conform to ISO4064 Standard Class B





2. Working condition:



--Water temperature≤50°c



--Water pressure≤1MPa (PN: 1.6MPa/16bar)



--ΔP≤0.1MPa(Class B)



--ΔP≤0.063MPa(R80/R100)





3. Accuracy:



From minimum flow-rate (qmin) inclusive, to transitional flow-rate (qt), exclusive:±5%



From transitional flow-rate (qt) inclusive, to overload flow-rate (qs), exclusive:±2%


Diameter (DN)
mm 15 20 25
flow ratio Q3/Q1 80 ~ 100
overload flow Q 4 M3/h 3.125 5 7.875
permanent flow Q 3 M3/h 2.5 4 6.3
transitional flow Q 2 M3/h 0.04 0.064 0.126
Min flowQ 1 M3/h 0.025 0.05 0.063
Pressure loss MPa ≤0.063
Max.pressure MPa ≤1
Water temperature °C 0.1--30
readings M3 0.0001 -- 9999
Communication interface M-Bus




4. Installation And Usage



Select the right water meter according to nominal flow rate which is less than or next to the rate through the pipe. It is not a good way for the user to buy the water meter based on the pipe size.



The place to be installed should be free from sunshine, frost, pollutant and water. During the period of frost, the inlet valve in the meter should be closed and the outlet valve and water tap should be open except for being packed for thermal insulation, thus to prevent the damage from being frozen.



Meter should be installed horizontally, and the digits on the dial is up to the face and arrow direction in the meter should be same with the flow.



The stone, sand and slight impurities in the new installed pipe should be cleared off for the sake of the meter fault.



For the purpose of metering accurately, the water tap should be higher than the meter.



Water meter should be not connected with pipe and there are live interface (e.g. pipe interface, connection screw, sealing washer etc.) between the meter and pipe. The meter should not be damaged due to the over-stress caused by pipe and its elements during installation.


Contact us if you need more details on Water Meter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Gauge、Cold Water Meter. If these products fail to match your need, please contact us and we would like to provide relevant information.