High Quality Energy Saving Packaged Unit, Free Cooling Precision Packaged Unit, Rooftop Air Conditioner Heat Pump Unit Suppliers in China

Home > Products > Data Terminal Units > Energy Saving Precision Packaged Unit

Energy Saving Precision Packaged Unit

  • Energy Saving Precision Packaged Unit
  • Energy Saving Precision Packaged Unit
  • Energy Saving Precision Packaged Unit
  • Energy Saving Precision Packaged Unit

Energy Saving Precision Packaged Unit

    Payment Type: L/C,T/T,Western Union
    Terms of Trade: FOB,CFR,CIF
    Min. Order: 1 Set/Sets
    Delivery Time: 30 Days
    Packaging: Plywood Package or Plastic Film Wrapped
    Productivity: 6000PCS/Year
    Brand: Amrta or OEM
    Transportation: Ocean
    Place of Origin: China
    HS Code: 8418612090
    Port: Qingdao,Shandong,China

Basic Info

Model No.: RTU()

Product Description

Rooftop packaged unit with free cooling which integrates condensing part, evaporating part & control part into a whole unit, firstly promoted & applied in South America, North Europe & Australia. It is air cooled direct evaporation & expansion air conditioner, has no need on cooling water & chilled water system, dispenses with cooling tower/cooling water pump/chilled water pump, relative pipe work, electric control & terminal equipments, saves user investment. It integrates evaporating part & condensing part into a whole unit which is installed outside to save indoor space, user will only need to install the duct, no need to connect refrigerant pipe work, it works under intellectual control without special care. Rooftop packaged unit is mainly applied to factories, schools, auditoriums, warehouses, etc.


Characteristics

Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Direct expansion coils with condensate drain tray.
Hermetic compressor
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
Centrifugal fan
Forward curve centrifugal fans for air treatment section and axial fans for condensation section.
Front, side and underside air discharge of the treatment unit.
High external pressure, long air supply distance.
Electric panel
Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.
Easy operation line controller
Cooling/Heating/Auto
Error indication
Timing on/off
Optional

Economizer with fresh, return air dampers and fresh air hood

Free cooling function for low ambient temperature

Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices
T3 (Tropical climate)
Roof curb
Metal/aluminum filter
100% heat recovery
Evaporating section: double skin with 50mm polyurethane foam
Optional water heating coil
Metal or plastic mesh on condenser coil
Optional supply/return air configurations
Upgraded plug fan
G4 filter, plate and bag filter
Fresh Air Rooftop Packaged Unit
Economizer and Free Cooling
It is one of the most important features of this rooftop as it maximise seasonal efficiency by reducing the use of thermodynamic cooling in mid season.
Thermodynamic cooling can be replaced by Free Cooling when outdoor temperature is below the building set point saving up to 15% on annual energy consumption.
Rooftop units are supplied with economizer and fresh air hood to improve comfort through better fresh air management and allow energy savings with free cooling.
Exhaust air
Gravity exhaust damper
Gravity exhaust damper Installed with economizer assembly, gravity exhaust damper relief pressure when outside air is being introduced in the system. It is a cheap and smart way to avoid over pressure in a building.
Power exhaust fans
Installed with economizer assembly, it provides exhaust air pressure relief when high levels of fresh air are being introduced in the system.

Interlocked to run when return air dampers are being closed and supply air blower is in operation. The extraction fans run when outdoor air dampers are at least 50% open (adjustable). It is also overload protected. A gravity exhaust damper is supplied with this option to prevent air from entering the unit during shutdown. The power exhaust fans have been size to exhaust 50% of the nominal air flow of the unit.

Economizer And Free Cooling

Technical Data

Model

RTU45

RTU50

RTU60

RTU75

RTU90

RTU105

Cooling capacity

kW

44.5

50

60

70

90

105

Heating capacity

kW

48.7

54.3

64

75.4

96.2

113.2

Power supply

380V / 3Ph / 50HZA

Cooling power input

kW

17

19.5

22.8

26.7

32.9

39.7

Heating power input

kW

15.6

18

21

24.8

30.4

36.7

Start current

A

168

186

175

199

197

266

Working current in cooling

A

31.7

35.6

39.9

48.3

61

70.6

Working current in heating

A

29.9

33.5

37.5

45.4

57.3

66.3

Throttle methods

Thermal expansion valve

Circuits

2

2

2

2

3

3

Refrigerant

R410A

Compressor

Type

Scroll type 380V / 3Ph / 50HZA

Qty

2

2

2

2

3

3

Condenser side

Condenser

Type

Al+copper tube

Axial fan

Qty

1

1

1

1

2

2

Drive

Direct drive

Motor power

kW

0.25

0.37

0.37

0.55

0.75

0.75

Air flow

m3 /h

4600

7800

7800

9000

12600

12600

Evaporator side

Evaporator

Type

Al+copper tube

Centrifugal fan

Qty

1

1

1

1

1

1

Motor power

kW

3

3

4

4

5.5

5.5

Air flow

m3 /h

7600

8500

10900

12500

16000

19500

Drive

Direct drive

Belt drive

External static pressure(Pa)

250

250

300

300

300

300

Filter

Aluminum frame filter G3

Noise level dB(A)

73

73

73

75

74

75

Dimension

L

mm

2268

2268

2298

2298

2878

2878

W

mm

1440

1440

1650

1650

2140

2270

H

mm

1167

1167

1400

1400

1964

1964

Weight

kg

750

770

830

860

1160

1350

* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 20.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.

Jinan Amrta Air Conditioning Co.,Ltd

 

AMRTA specialize in commercial air conditioner and cooling system solutions for commercial and industrial use. Our products cover water chiller, Rooftop packaged unit, heat pump and fan coil units etc.

We AMRTA constantly build upon our history of proven innovation with new products and services that improve global comfort and efficiency.

AMRTA offer extraordinarily innovative and exceptionally reliable service, so why would you install anything but AMRTA? Please check our website

Company Info

  • Company Name: Jinan Amrta Air Conditioning Co.,Ltd
  • Representative: Haiyan Wang
  • Product/Service: Water Chiller , Air Conditioner , Rooftop Packaged Unit , Heat Pump System , Fan Coil , Air Handling Systems
  • Capital (Million US $): US$5 Million
  • Year Established: 2012
  • Total Annual Sales Volume (Million US $): US$2.5 Million - US$5 Million
  • Export Percentage: 61% - 70%
  • Total Annual Purchase Volume (Million US $): Below US$1 Million
  • No. of Production Lines: 5
  • No. of R&D Staff: 5 -10 People
  • No. of QC Staff: 5 -10 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): 10,000-30,000 square meters
  • Factory Location: No. 13788 Century Road, Jinna, Shandong, P.R.China
  • Contact Person: Mr. Richard Lee
  • Tel: 0086-531-88901036
Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters